AG - Autogenous & SAG Semi-Autogenous Mill Design …
Product Size: All passing 6 mesh with 80% passing 20 mesh. Net power from pilot plant: 16.5 KWH/ST. Mill, gear and pinion friction multiplier: 1.025. Mill Power required at pinionshaft = (240 x 16.5 x 1.025) ÷ 0.746 = 5440 Hp. Speed reducer efficiency: 98%. 5440 Hp ÷ 0.98 = 5550 HP (required minimum motor output power).